It's no secret that air conditioning is essential to keeping your home cool during the hot summer months. But when your split AC compressor isn't working correctly, it can be quite a challenge to solve the problem and get your AC unit running smoothly again.


In this guide, we will discuss some of the common causes of why your split AC compressor might not be working, as well as how to troubleshoot and fix these problems. By understanding the different issues that can arise with an AC compressor, you’ll be able to identify and address any issues quickly in order to avoid costly repairs and enjoy your cool, comfortable home all season long.

Understanding the Split AC Compressor:

Symptoms of a Non-Functioning Split AC Compressor:

Reasons for Split AC Compressor Not Working:

Introduction:

Troubleshooting the Split AC Compressor:

Hiring a Professional:

Preventive Maintenance:

4. Introduction

Split AC compressor not working can be frustrating for homeowners. It can be caused by various problems, and troubleshooting the issue can be a daunting task. In this troubleshooting guide, we will cover the common causes and solutions for split AC compressor not working.

2 Basic checks

Before diving into complex issues, it's important to perform basic checks, such as checking the thermostat settings, circuit breaker, air filter, and power supply to the AC unit. These basic checks can often identify the cause of the problem and save time and money.

3 Refrigerant leak:

One of the most common problems that cause the split AC compressor not working is a refrigerant leak. Low refrigerant levels can cause the compressor to stop working or damage it. Signs of refrigerant leak include warm air blowing from the AC unit, hissing or bubbling noise, and ice forming on the compressor or refrigerant lines. It's important to call a professional HVAC technician to fix the leak and recharge the system.

4 Faulty compressor

Another possible cause for the split AC compressor not working is a faulty compressor. Signs of a faulty compressor include unusual noises, such as grinding or clicking, and failure to start. In this case, the compressor may need repair or replacement.

5 Electrical problems:

Electrical problems, such as a blown fuse, faulty wiring, or a malfunctioning capacitor, can also cause the split AC compressor not working. These issues can prevent the compressor from receiving the necessary power to start or run. Only a licensed electrician or HVAC technician should handle electrical problems.

 Split AC compressor not working is a common problem that can have various causes, including refrigerant leak, faulty compressor, or electrical problems. Basic checks should be performed before calling a professional, and any issues related to refrigerant or electricals should be handled by a licensed HVAC technician or electrician.

1. Understanding the Split AC Compressor:

Understanding the Split AC Compressor is crucial to troubleshooting when your Split AC compressor isn't working. You can start by checking the power supply and the condition of the compressor. Here are some steps that you can follow to troubleshoot the problem:

1. One of the first things to check when the compressor is not working is the power supply. Ensure that the AC unit is receiving electricity by checking the breaker and fuse box.

2. Check the contactor switch of the compressor. If it appears burnt, it needs to be replaced.

3. Inspect the capacitor. "A bad capacitor can prevent the motor from starting in the first place or cause it to overheat once it does start" (Source: The Spruce).

4. Check if the motor is running but the compressor isn't. This could be an indication of a bad compressor.

While these steps may help diagnose the issue with your Split AC compressor, it is always recommended to seek help from a certified professional for a thorough checkup.

 Troubleshooting a Split AC compressor involves checking the power supply, contactor switch, capacitor, and motor. Seek professional help if unsure about any of these steps.

3. Reasons for Split AC Compressor Not Working:

There can be various reasons why a split AC compressor may stop working. Focusing on the top 3 reasons, let's dive into the possible causes and solutions to troubleshoot the problem.

1. Power Supply Issues: One of the most common causes for a split AC compressor to stop working is due to power supply issues. This may be caused by a tripped circuit breaker, a blown fuse, loose connections or a faulty thermostat. If the compressor doesn't receive the necessary amount of power, it may not work correctly or fail to work at all. In such cases, it's important to check the circuit breaker, the thermostat, the power supply to the unit, and verify the connections are tight and secure.

2. Dirty or Clogged Air Filter: A dirty or clogged air filter can also lead to a malfunctioning split AC compressor. If the air filter is not cleaned or replaced regularly, it can cause strain on the compressor and hinder its efficiency. Over time, this strain can cause damage to the compressor or lead to it not working altogether. It's recommended to replace or clean the air filters every three months, depending on usage.

3. Faulty Fan Motor: The fan motor plays a crucial role in the functioning of the split AC's compressor. If the fan motor is not working correctly, it can stop the compressor from working. A worn-out fan motor can cause the compressor to overheat, and eventually fizzle out. If the fan motor appears to be damaged or not working at all, it is best to have it fixed or replaced by a professional technician.

By understanding these possible causes and solutions to split AC compressor malfunctioning, you can properly troubleshoot the issue and get your AC back up and running efficiently.

Split AC compressor not working may be due to power supply issues, dirty or clogged air filters, or faulty fans. Regular maintenance can ensure a healthy and efficient AC unit.

2. Symptoms of a Non-Functioning Split AC Compressor:

If you own a split AC, you must have experienced issues with split AC compressor not working at some point. The compressor is the most important component of an AC, and without it, the AC cannot function properly. In this troubleshooting guide, we'll discuss the 4 most common symptoms that indicate your split AC compressor isn't working properly.

**1. No cool air from the AC vents**

If you turn on your split AC, but no cool air comes out from the vents, it's highly likely that your compressor isn't functioning properly. This could be caused by a variety of issues, including a refrigerant leak, electrical fault, or a damaged compressor.

**2. Loud or unusual noises**

If you hear loud or unusual noises coming from your split AC, it could be a sign that your compressor is experiencing issues. Some of the most common noises include clanking, thumping, or hissing sounds, which could indicate issues such as internal component damage or low refrigerant levels.

**3. Tripped circuit breaker**

If you AC trips the circuit breaker frequently, it could indicate a problem with your compressor. This could be caused by overheating, electrical faults, or damage to the compressor or other components.

**4. High energy bills**

If you notice a sudden increase in your energy bills, it could be due to a malfunctioning compressor. A compressor that's not functioning efficiently will run for longer periods of time, consuming more energy and increasing your energy bills in the process.

5. Troubleshooting the Split AC Compressor:

If your split AC compressor is not working, it could be due to various reasons. Here are some steps you can take to troubleshoot the problem:

1. Check the power supply: Make sure the AC unit is connected to a power supply and the fuse or circuit breaker is not blown. If it is, replace the fuse or reset the circuit breaker.

2. Check the thermostat: If the thermostat is not set correctly, the compressor may not turn on. Make sure the thermostat is set to the correct temperature and mode.

3. Check the air filter: A dirty air filter can cause the AC unit to malfunction by reducing airflow. Clean or replace the air filter regularly.

4. Check for refrigerant leaks: Low refrigerant levels in the AC unit can cause the compressor to stop working. Check for any leaks and repair them if necessary.

5. Check the compressor: If none of the above steps work, there may be a problem with the compressor itself. Contact a professional HVAC technician to inspect and repair the compressor.

7. Preventive Maintenance:

Split AC compressor not working is a common issue faced by many homeowners, especially during hot summers. In this section, we will discuss some preventive measures that can be taken to troubleshoot issues with the Split AC compressor.

Check your thermostat:

One of the reasons for the Split AC compressor not working may be because of an incorrect thermostat setting. Ensure that your thermostat is set to "cool" mode and the required temperature is set.

Circuit breaker

The next thing you can check is the circuit breaker. Sometimes, the circuit breaker may trip and disrupt the power supply to the Split AC unit. In such cases, flip the circuit breaker to the "on" position and give it a few minutes to start the compressor.

Dirty compressor:

If the Split AC compressor is not working or not functioning correctly, it could be due to a dirty compressor. Dirt and debris can accumulate over time and cause the compressor to seize up. Make sure to regularly clean your compressor and remove any dirt or debris from the outdoor unit.

Refrigerant leak:

Another possible cause of a non-functional Split AC compressor could be a refrigerant leak. Inspect the refrigerant lines and ensure there are no leaks. If you notice any leaks, it is best to contact a professional technician to address the issue.

these are some preventive measures to troubleshoot a non-functional Split AC compressor:

Check your thermostat setting

Verify your circuit breaker

Clean your compressor regularly

Inspect refrigerant lines for leaks


How can I prevent Split AC Compressor failure?

Split AC Compressor failures are typically caused by a lack of lubrication, dust build-up, or improper installation. To prevent this from happening in the first place, keep the compressor clean and free of debris. Additionally, make sure the unit is properly installed and that the required amount of lubricant is applied.

What is a split AC compressor?

A split AC compressor is a type of air conditioning compressor used in split system applications. It is a smaller, lower-powered compressor that is used to provide supplemental cooling for a single room or suite.

How do I know if I need a professional to fix my Split AC Compressor?

If the compressor doesn't seem to be working, or if it's been awhile since the last maintenance check, it might be a good idea to have a professional take a look. A compressor that's not working properly can lead to high energy bills and other problems.

How can I troubleshoot a Split AC Compressor?

Verify that the compressor is properly connected to the AC unit and the power source. Check that the compressor’s filters are clean and in good condition. Verify that the compressor is properly filled with air. Check the AC unit’s wiring for signs of damage. Test the compressor’s power by turning on the AC unit and checking for signs of noise or distortion.

What are the reasons for a Split AC Compressor not working?

There are a few potential reasons why a split AC compressor might not be working. Below are a few of the most common issues and how to troubleshoot them. Dirty filters: A dirty filter will block airflow, leading to a compressor failure. To check filters, turn off the power to the unit, remove the filters, and clean them with a solvent such as acetone. Replace the filters when they are clean. Insufficient air flow: If the unit doesn't have enough air flow, the compressor will overheat and fail. To check if there is enough air flow, turn on the power to the unit and open all the windows. If the unit starts, the air flow is insufficient, and you will need to replace the unit.