Carrier Inverter AC Error Codes

Carrier Inverter AC Error Codes


Indoor Error Code

E0 Indoor Unit EEPROM Parameter Error.

E1 indoor / outdoor units communication error.

E3 indoor fan speed out of control.

E4 indoor room temperature sensor T1 short circuit or open circuit.

E5 Evaporator Coil Temperature Sensor T2 short circuit or open circuit.


EC refrigerant leak detection.


F1 outdoor ambient temperature sensor T4 short circuit or open circuit.


F2 condenser coil temperature sensor T3 short circuit or open circuit.


F3 compressor discharge temperature sensor T5 short circuit or open circuit.


F4 outdoor unit EEPROM parameter error.


F5 outdoor fan speed out of control.


P0 IPM malfunction or stronger current protection than IGBT.


P1 over voltage or low voltage protection.


P2 high temperature safety compressor is the top diagnosis and solution.


P4 inverter compressor drive error,


P5 Mode Conflict.


P6 Compressor Voltage Protection.


Outdoor Error Code:


Error code meaning


E0 Outdoor EEPROM Malfunction


E2 indoor / outdoor units communication error


E3 communication malfunction between IP3 board and outdoor main board


Open or short circuit of E4 outdoor unit temperature sensor.


E5 Voltage Protection.


E8 outdoor fan speed malfunction.


F1 Neither an indoor unit coil outlet temperature sensor or sensor connector is faulty.


F2 No B Indoor unit coil outlet temperature sensor or sensor connector is faulty.


F3 No C Indoor unit coil outlet temperature sensor or sensor connector is faulty.


F4 No D Indoor unit coil outlet temperature sensor or sensor connector is faulty.


F5 No E Indoor unit coil outlet temperature sensor or sensor connector is defective.


P1 High Pressure Protection.


P2 low pressure protection.


Current protection of p3 compressor.


P4 temperature protection of compressor.


High Temperature Protection of P5 Condenser.


P6 IPM Module Security.


Outdoor checking function

00: normal performance

01: Number of indoor units in good relationship


02: outdoor unit running mode


03: HP capacity of an indoor unit


04: B Indoor Unit Capacity HP


05: C indoor unit capacity HP


06: D indoor unit capacity HP


07: E indoor unit capacity H.P.


08: An Indoor Unit Capacity Demand Code


09: B Indoor Unit Capacity Demand Code


10: C Indoor Unit Capacity Demand Code


11: D Indoor Unit Capacity Demand Code


12: e indoor unit capacity demand code


13: Total Indoor Units Modification Capacity Demand Code


14: Target Frequency, Demand Capacity Capacity for Total Indoor Units


15: Target frequency after frequency range


16: Compressor control chip is for sending target frequency


17: An indoor unit evaporator outlet temp.


18: B indoor unit evaporator outlet temp.


19: C indoor unit evaporator outlet temp


20: D indoor unit evaporator outlet temp.


21: e indoor unit evaporator outlet temp.


22: An indoor unit room tem.


23: B indoor unit room tem.


24: C indoor unit room tem.


25: D indoor unit room tem.


26: e indoor unit room tem.


27: An indoor unit evaporator temp.


28: B indoor unit evaporator temp.


29: C indoor unit evaporator temp.


30: D indoor unit evaporator temp.


31: E indoor unit evaporator temp.


32: Condenser Pipe Temp. (T3)


33: Outdoor Temperry. (T4)


34: Compressor Discharge Temp. (Tp)


35: AD value 0f current


36: AD value of voltage


37: EEV open angle forA indoor unit


38: B EEV open angle for indoor unit


EEV open angle for 39: C indoor unit


EEV open angle for 40: D indoor unit


41: EEV open angle for E indoor unit


42: frequency limit symbol


43: average value of T2


44: outer fan speed


45: Last error or security code


Error Code: 0C

Reason for Operation: Disconnection of short–circuit or room temperature sensor (TA sensor).


Error Code: 0D

Reason for operation: out of place, disconnection, short-circuit, or migration of heat exchanger sensor (TC sensor)


Error Code: 11

Reason for operation: trouble with indoor fan lock or indoor fan circuit


Error Code: 12

Reason for operation: Other indoor P.C. Trouble on. The boards


Error Code: 04

Reason for Operation: The serial signal returned from the started operation is not sent to the indoor side. (1) Defective wiring of connecting cable (2) Operation of compressor thermo. Gas shortage gas leakage


Error Code: 05

Reason for Operation: The operation command signal is not sent to the outer side.


Error Code: 14

Reason for Operation: The inverter operates an over–current protective circuit. (Less time)


Error Code: 16

Reason for operation: Position-detect circuit error or short-circuit between windings of the compressor


Error Code: 17

Reason for operation: current-address circuit error


Error Code: 18

Reason for operation: Out of place, disconnected or short-circuited outdoor tem. The sensor


Error Code: 19

Reason for operation: Disconnection or short-circuit of discharge tem. The sensor


Error Code: 1A

Reason for operation: outdoor fan drive system error


Error Code: 1B

Reason for operation: outdoor heat exchanger temp. Sensor error


Error Code: 1C

Reason for operation: compressor drive output error, compressor error (lock, missing etc.), break down


Error Code: 07

Reason for Operation: The return serial signal has been sent when the operation started, but has not been sent halfway through.


Error Code: 1D

Reason for operation: The compressor does not rotate.


Error Code: 1E

Reason for Operation: Discharge Temp. Exceeded 117 ° C


Error Code: 1F

Reason for operation: breakdown of the compressor.


Error Code: 08

Reason for operation: four-way valve inversion error.



Code: 1 heat exchanger sensor (TE) error


Code: 2 suction sensor (TS) error


Code: 3 Hot Gas Discharge Sensor (TD) ERMR


Code: 4 high pressure proteomian error


Code: 5 outdoor air temperature sensor error (TO)


Code: 6 outdoor DC fan motor error


Code: 7 communication error between IPDU (abnormal stop)


Code: 8 high pressure release operation


Code: 9 Discharge Temp. Error: hot gas is too high


Code: 10 EEPROM Error


Code: 11 Communication error between IPDU (no abnormal stop)


Code: 12 G-Tr short-circuit protection


Code: 13 Find circuit error


Code: 14 current sensor error


Code: 15 comp. Lock error


Code: 16 COMP. the division


Inner detachment:


Code: 2 compaction pump failure or drainage failure


Code: 3 Indoor Unit Room Air Sensor Fault.


Code: 4 Indoor Unit TC Coil Sensor Fault.


Code: 10 Indoor Unit Software Fault (EEPROM Corrupt)


Code: 12 Indoor Unit Software Fault (Address / Zone Corrupt)


Code: 14 loss of signal from CDU


Code: 15 Indoor Unit Tcj Coil Sensor Fault


Code: 18 outdoor unit control box faults (G-Tr short circuit protection)


Code: 20 status check circuit error


Code: 21 outdoor unit current sensor fault


Code: 22 outdoor unit heat exchange sensor fault


Code: 23 outdoor unit discharge temperature sensor fault


Code: 24 Outdoor Unit Fan Fault


Code: 26 other external unit fault


Code: 27 outdoor unit compressor lock


Code: 28 outdoor unit discharge temperature defect


Code: 29 outdoor unit compressor breakdown


Code: 31 outdoor unit high temperature release