Carrier Window Room Air Conditioner Error Code

 Carrier Window Room Air Conditioner Error Code

E1: Loss of communication between the CCC 2 thermostat and an individual system power module board. The LED error code will display the EI and the communication lost area number. Any additional area that would blink other than the loose communication current area.

E2: Open circuit or out-of-the-range indoor temperature sensor. All heat, cool and dehumidify operations will be shut out. Manual fan operation will continue.

E3: Indoor Temperature Sensor. All heat, cool, and dehumidify operations will be stopped outside. Manual fan operation will continue.

E4: Open circuit or out of range outdoor temperature sensor (select model). The heat pump and dehydration operation will be discontinued. Air conditioners, furnaces, heat strips and fans may continue to operate.

E5: Open circuit or out of range freeze sensor. Air conditioners and dehumidification operations will be locked. Heat pumps, furnaces, heat strips and fans may continue to operate but the final temperature represents the set-point.

E6: Open Circuit Humidity Sensor (Select Model). Air conditioners and dehumidification will be locked. The heat pump, furnace heat strip and fan can continue to operate.

E7: Loss of 120 VAC power to all power module boards on the system. The system will shut down.

E8: Invalid zone configuration. Both the heat pump and the heat strip DIP switch are in the ON position in the same area. The heat pump, heat strip, air conditioner and dehumidify operation will be shut down in the affected area.

E9: Invalid zone configuration. Dehumidifier DIP switches and either heat pump or heat strip DIP switches are set to ON positions in a zone. The heat pump, heat strip, air conditioner and dehumidify operation will be shut down in the affected area.

Sometimes a breaker will look as if it is in operating condition but has actually tripped. Be sure to flip the breaker lever to ‘OFF’ and then return to “ON” with the corresponding click.

Other error code

nF: Air Filter Replacement Reminder: After 2,880 hours of use, the display window “nF” will flash on the indoor unit. This is a reminder to change your filter. After 15 seconds, the unit will return to its previous performance. To reset the reminder, press the LED button 4 times on your remote control, or the MANUAL CONTROL button 3 times. If you do not reset the reminder, the “nF” indicator will flash again upon restarting the unit.

CL: Air Filter Cleaning Reminder: After 240 hours of use, the display window “CL” will flash on the indoor unit. This is a reminder to clean your filter. After 15 seconds, the unit will return to its previous performance. To reset the reminder, press the LED button 4 times on your remote control, or the MANUAL CONTROL button 3 times. If you do not reset the reminder, the “CL” indicator will flash again upon restarting the unit.

EC: Refrigerant leakage detection: Indoor unit will automatically display “EC” The “timer” indicator light goes off and the “run” indicator light flashes 7 times when the unit detects a refrigerant leak

Error code trouble

08 defrost mode 1

0A Defrost Mode 2

F0 low charge or refrigeration system interruption

F3 Outdoor Ambient Temperature Sensor Malfunction

F4 outdoor mid-coil temperature sensor malfunction

F5 outdoor discharge air temperature sensor

F7 cooling oil return cycle

E1 System High Pressure Protection

E2 Indoor Freeze Protection

E3 System Low Pressure Protection

E4 Compressor Discharge High Temperature Protection

E6 communication error between indoor and outdoor

E7 mode conflict

E8 System Overload Protection

E9 Cold Blow Protection

dd test mode

Pho pump down mode

P0 IPM left

P5 Compressor Current Protection

P6 communication error between inverter drive and main board

P7 heat sink temperature sensor malfunction

P8 IPM over temperature protection


P9 open contactor


PC current sensor malfunction


PD current sensor incorrect wiring protection


PA input current protection


PF inverter board ambient temperature sensor malfunction


PL low voltage protection


PH high voltage protection


PP abnormal input AC voltage


Pu capacitor charging malfunction


H1 heating oil return cycle


H2 forced defrost


H3 Compressor Overheat Protection


H5 IPM Security


H7 compressor speed reduction


HC PFC Board Security


L9 Compressor High Voltage Protection


Lc compressor start-up failure


LD Compressor Phase Loss Protection


Take compressor standstill


LF Compressor Over-Speed ​​Protection


A5 condenser coil inlet temp sensor sensor malfunction


A7 condenser outlet temperature sensor malfunction


EE memory card error


N frequency limit for module circuit protection


EU frequency limit for module temperature protection


F6 frequency limit for overload protection


F8 frequency limit for system circuit protection


F9 frequency limit for module circuit protection


FH frequency limit for freeze protection


Damaging His Majesty’s Compressor Safety


LP indoor and outdoor units are mismatched


U1 Compressor Phase Detection Malfunction


U3 Low DC Bus Voltage


dn communication error between main board and EXV


13 unit one indoor pipe outlet temperature sensor malfunction


14 unit one indoor pipe inlet temperature sensor malfunction


15 unit one indoor return air sensor malfunction


16 unit one mode conflict


17 Unit A Freeze Protection


23 unit B indoor pipe outlet temperature sensor malfunction


24 unit B indoor pipe inlet temperature sensor malfunction


25 unit B indoor return air sensor malfunction


26 unit B mode conflict


27 Unit B Freeze Protection


33 unit C indoor unit pipe outlet temperature sensor malfunction


34 Unit C Indoor Unit Pipe Inlet Temperature Sensor Malfunction


35 unit C indoor unit return air sensor malfunction


36 unit C mode conflict


37 Unit C Freeze Protection


41 unit D communication error


42 indoor return air temperature sensor malfunction


43 Unit D Indoor Pipe Outlet Temperature Sensor Malfunction


44 Unit D Indoor Pipe Inlet Temperature Sensor Malfunction


45 unit d indoor return air temperature sensor malfunction


46 unit d mode conflict


47 Unit D Freeze Protection


51 unit e communication error


52 Unit E Indoor Pipe Midway Temperature Sensor Malfunction


53 Unit E Indoor Pipe Outlet Temperature Sensor Malfunction


54 Unit E Indoor Pipe Inlet Temperature Sensor Malfunction


55 unit e indoor return air temperature sensor malfunction


56 unit E mode conflict


57 Unit E Freeze Protection


C5 jumper replacement is missing on indoor board